Firman Generator Electric Start Not Working
|

Firman Generator Electric Start Not Working

There are a few possible problems that could be the root of your Firman generator electric start not working. The common reasons for electric start issues with Firman generators will be briefly described in detail, along with some potential fixes.

Causes Of Firman Generator Electric Start Not Working

Faulty Starter Motor

A faulty starter motor is one of the potential causes of electric start problem. The starter motor is responsible for turning the engine over and starting it, so if it is not functioning properly, the generator will not start.

Generator Faulty Starter Motor
generator Faulty Starter Motor

If you suspect that the starter motor is the issue, you can try to start the generator manually using the pull start. If the generator starts with the pull start, then the starter motor is likely the problem.

To fix a faulty starter motor, You must change it out for a new one. This is a somewhat complicated fix that calls for considerable mechanical expertise. It is advised that you use a certified technician’s aid when changing the starter motor on your Firman generator.

Faulty Starter Solenoid

A faulty starter solenoid is one of the potential causes of electric start problems in Firman generators. The generator won’t start if the starter solenoid isn’t working properly since it acts as a switch to engage the starter motor.

Generator Faulty Starter Solenoid
generator Faulty Starter Solenoid

You can try to get around the starter solenoid if you think it’s the problem by directly connecting the starter motor to the battery. To begin, confirm that the fuel valve is closed and the generator is off. Then, use a pair of jumper cables to connect the positive terminal of the battery to the positive terminal of the starter motor, and the negative terminal of the battery to the negative terminal of the starter motor.

If the generator starts with the starter motor jumping directly from the battery, then the starter solenoid is likely the problem. You must swap out a damaged starter solenoid for a new one in order to repair it. With some basic mechanical knowledge and the right equipment, this repair is rather easy to complete.

Dead Battery

If the battery is dead, it will not be able to provide the electrical power needed to start the generator, and the generator will not start.

Firman Generator Dead Battery
Firman Generator Dead Battery

A voltmeter can be used to check the battery’s voltage in order to identify a dead battery. The battery needs to be replaced if the voltage drops below 12.5 volts, which indicates that it is likely dead. You must install a fresh battery in order to fix a dead one. Make sure the generator is off and the fuel valve is closed before you start. Then, remove the old battery from the generator and install the new one, making sure to connect the positive and negative terminals correctly.

Once the new battery is installed, you can try to start the generator using the electric start. If the generator still continually begins to rise, the battery will not be able to provide the electrical power needed to start the generator, and No electric power is being produced by the generator, which won’t start.

Faulty Ignition Switch

A faulty ignition switch is one of the possible reasons for electric start problems in Firman generators. The ignition switch is the switch that is used to turn the generator on and off, and it is also used to engage the starter motor. If the ignition switch is not functioning properly, the generator will not start.

You can attempt to manually start the generator using the pull start in order to identify a bad ignition switch. The ignition switch is probably the issue if the generator starts with a pull start but not an electric start. A broken ignition switch needs to be replaced in order to be fixed. This is a relatively simple repair that can be done with basic mechanical knowledge and tools.

Clogged Fuel System

One of the possible causes of electric start issues with Firman generators is a clogged fuel system. If the fuel system is clogged, it will not be able to deliver fuel to the engine, and the generator will not start.

To diagnose a clogged fuel system, you can try to start the generator manually using the pull start. If the generator does not start with the pull start, then the fuel system is likely the problem.

To fix a clogged fuel system, you will need to clean the fuel system. This will involve draining the fuel tank, removing the fuel filter and cleaning it, and cleaning any other parts of the fuel system that may be clogged. This is a relatively complex repair that will require some mechanical knowledge and experience.

Common Causes Of Firman Generator Electric Start Issues Infographic
Common Causes of Firman Generator Electric Start Issues infographic

Few Steps You Can Try If Your Generator’s Electric Start Is Not Working

There are a few things you can do to fix your generator’s electric start if it stops functioning:

  • Make sure the battery is charged and working correctly by checking it. The battery cannot power the electric starter if it is dead or not functioning properly.
  • Verify the wiring running to and from the starter switch. Verify that the wiring is firmly connected and undamaged and that the switch is in the “on” position.
  • To ensure appropriate operation, inspect the starter motor. The electric starting is powered by the starter motor, thus if it isn’t working properly, the electric starter won’t operate.
  • The starter motor may need to be changed if it is not operating properly. To test if any trapped pieces can be released, you can try tapping the starter motor with a hammer; but, if it doesn’t work, you will probably need to replace the starter motor.
  • You might have to manually pull the pull cord to start the generator if none of the aforementioned attempts succeed. Be sure to adhere to the manufacturer’s recommendations while manually starting the generator.

In order to avoid problems like these, it is generally a good idea to routinely repair your generator and keep it in good operating order. This could entail cleaning the spark plug, checking the oil level, and inspecting and changing the battery.

Safety Precautions For Troubleshoot The Electric Start On Firman Generator?

It is essential to take the following safety precautions:

  • Disconnect the generator from any power source, including the main power supply and any external fuel sources, to prevent electrical shocks or fires.
  • Wear protective gear, such as rubber gloves and safety glasses, to protect yourself from any electrical shocks or debris that may be generated during the troubleshooting process.
  • Make sure the generator is in a well-ventilated area to prevent the build-up of harmful fumes or gases.
  • For safety measures against electric shocks, make sure the generator is correctly grounded.
  • Keep flammable materials, such as gasoline or other fuels, away from the generator to prevent fires.
  • Do not attempt to open or disassemble the generator unless you are trained and qualified to do so. If you are not confident in your abilities, contact a certified electrician or the manufacturer for assistance.

Conclusion

There are a number of probable reasons why your Firman generator might not be starting with an electric kick, as well as a number of alternative solutions you could try. This article will give a general overview of several typical reasons why Firman generators experience electric start issues as well as some potential fixes.

FAQs

  • What Should I Do If My Firman Generator’s Electric Start Is Not Working?

    If your generator’s electric start is not working, the first step is to check the battery to make sure it is charged and functioning properly. You should also check the starter switch and the wiring leading to it, as well as the starter motor to ensure it is functioning properly. If none of these steps resolve the issue, you may need to start the generator manually using the pull cord.

  • How Can I Check The Battery On My Firman Generator?

    To check the battery on your generator, you will need a voltmeter. Begin by turning off the generator and removing the battery from the generator. Then, connect the voltmeter to the battery terminals and check the reading. If the reading is below 12.4 volts, the battery may be dead or not functioning properly and will need to be replaced.

  • Can I Start My Firman Generator Manually If The Electric Start Is Not Working?

    Yes, if the electric start on your generator is not working, you can try starting it manually using the pull cord. Make sure to follow the manufacturer’s instructions for starting the generator manually, and be aware that starting the generator manually may be more difficult than using the electric start.

  • How Do I Troubleshoot The Electric Start On My Firman Generator?

    To troubleshoot the electric start on your Firman generator, you will need to check the battery, starter switch, and wiring, as well as the starter motor. If any of these components are not functioning properly, they may be the cause of the issue. You may need to replace the battery, repair or replace damaged wiring, or replace the starter motor if it is not functioning properly.

  • What Should I Do If The Starter Motor On My Firman Generator Is Not Working?

    If the starter motor on your generator is not working, you may be able to free up any stuck parts by tapping on the starter motor with a hammer. If this does not work, you will likely need to replace the starter motor. You can try replacing the starter motor yourself or hire a professional to do it for you.

  • How Can I Prevent My Firman Generator’s Electric Start From Not Working In The Future?

    To prevent your generator’s electric start from not working in the future, you should regularly maintain your generator and keep it in good working order. This may involve checking and replacing the battery, cleaning the spark plug, and checking the oil level. Additionally, be sure to follow the manufacturer’s instructions and maintain your generator.

  • Can I Repair The Electric Start On My Firman Generator Myself, Or Do I Need To Hire A Professional?

    In some cases, you may be able to repair the electric start on your generator yourself, such as by replacing the battery or repairing damaged wiring. However, if the issue is more complex, such as a faulty starter motor, you may need to hire a professional to repair the electric start on your generator.